[Roadmap Phase 3] DS Pilot, DSD Diagnostics, Quality Traceability & Recovery
Phase 3 Overview · Status: Live (
DS Pilot(Plan·Dashboard·Equipment Doctor) ·origin flow·interlock)Connects digital process plans (
DSL+AAS) to execution, state observation, and diagnostics via DS Pilot (CONCEPT_AND_SCOPED_DELIVERY,physicalAcceptance = NOT_RUN), helping operators recover safely while preserving WIP state.
1. Phase 3 Highlights
Area · What It Delivers
**Log Reverse-Synthesis (dsdx.dsd.*)** · Reconstructs .ds2 sequences and baseline timing directly from field PLC/sensor logs for DS Pilot Equipment Doctor.
Zero-Write Field OEE & 8 KPIs · Collects live OEE (A × P × Q) with a read-only adapter that never alters live PLC outputs (Guide 05). {{Details::Honest Metrics: Deduplicates overlapping stops once via union and displays NOT_APPLICABLE instead of fake 0 when field KPIs are unmeasured (physicalAcceptance = NOT_RUN).}}
Sensorless Quality Traceability · Correlates cylinder cycle timing trends with quality results to locate worn upstream actuators early. {{Details::Alerts & Reports: Raises pre-defect warnings, flags suspicious parts, and exports .shadow.xlsx ledgers (2 or 4 sheets) and .dpp.aasx records.}}
Cold-Boot Homing, DS Pilot & Recovery Preservation · Models with origin flow cold-boot in 10(ORIGIN_REQ) gating AUTO until 30(AUTO_READY) and wire origin api to HMI_TR_TO_HOMING; recovery STOP/HOMING preserves WIP tokens & Finish across Auto and Manual Jog. {{Details::Safety, Heartbeat & HILS: Client 200ms HMI_HEARTBEAT_IN (500ms watchdog), Work.Id jog tags (EXPORT-E500), --local-agent loopback HILS, FAIL fault sealing until authentic HMI_SYS_STATE recovery, and DS Pilot (Plan · Dashboard · Equipment Doctor, CONCEPT_AND_SCOPED_DELIVERY).}}
2. Phase 3 Reference Model (ds2 v2;)
ds2 v2;
project Milestone3_SmartRecovery {
active WelderStation;
system WeldGun {
flow Act {
work Weld { duration 350ms; }
work Retract finished { duration 200ms; }
Weld <|> Retract;
}
api Weld = Act.Weld;
api Retract = Act.Retract;
observe IsRetracted = Act.Retract;
}
system ClampJig {
flow Act {
work Lock { duration 200ms; }
work Unlock finished { duration 200ms; }
Lock <|> Unlock;
}
api Lock = Act.Lock;
api Unlock = Act.Unlock;
}
system WelderStation {
origin flow RecoveryHome {
work GunRetractFirst {
WeldGun.Retract reuse completed;
}
work JigUnlockSecond {
interlock (WeldGun.IsRetracted) "Retract weld gun before unlocking jig";
ClampJig.Unlock reuse completed;
}
GunRetractFirst => JigUnlockSecond;
}
flow WeldCycle {
work SpotWeld {
ClampJig.Lock > WeldGun.Weld > WeldGun.Retract > ClampJig.Unlock;
}
}
}
}